Date20.04.2026
SubjectALFAcross *80, Musterprüfnummer EP 323.2021, ALFAcross *100, Musterprüfnummer EP 218.2018, ALFAcross *115, Musterprüfnummer EP 150.2016, ALFAcross *120, Musterprüfnummer EP 321.2021, ALFAcross *140, Musterprüfnummer EP 242.2018, ALFAcross *220, Musterprüfnummer EP.263.2019,
 
During gym rescue training exercises, there were two instances where an inner container panel became caught on the inner container’s closure loop (rubber). As a result, the inner container was unable to release the rescuer. The manufacturer has determined that this is related to the inner container closure method described in the manual.

All details

Fluggeräte GmbH Safety Notice

Owners who have packed their AlfaCross rescue parachute according to the previous packing instructions are requested to check the packing. If necessary, repacking must be performed in accordance with the new packing instructions, which are described in an updated version of the manual. The updated packing instructions are mandatory.

This measure must be carried out before the next use.